100G 48-channel Flat Top Gaussian AAWG Module
The module supports 48 channels, the channel spacing is 100GHz, the channel uniformity is as high as ±0.05dB, the channel insertion loss is as low as below 5dB, and the channel isolation is above 25dB. These excellent technical indicators can help you achieve more efficient data transmission. In addition, the module also supports RS232 management interface and single 12V power supply, which is easy to operate and easy to integrate.
- Product Introduction
The module supports 48 channels, the channel spacing is 100GHz, the channel uniformity is as high as ±0.05dB, the channel insertion loss is as low as below 5dB, and the channel isolation is above 25dB. These excellent technical indicators can help you achieve more efficient data transmission. In addition, the module also supports RS232 management interface and single 12V power supply, which is easy to operate and easy to integrate.
This module is widely used in communications, radio and television, computer rooms and other fields, and can meet your needs for high-speed data transmission. No matter in terms of data transmission speed, stability, or the number of channels, our 100G 48-channel Flat Top Gaussian AAWG module can provide you with the best solution.
We always adhere to customer demand-oriented, continuously improve product performance and stability, and provide you with better products and services. If you are interested in our products, please feel free to contact us, we will serve you wholeheartedly.
Product Features
1. High number of channels: The module supports 48 channels, which can meet the needs of high-speed data transmission and provide greater data transmission capacity.
2. Flat-topped Gaussian technology: The module adopts advanced flat-topped Gaussian technology, which can provide lower insertion loss and higher channel uniformity, ensuring the stability and reliability of data transmission.
3. Excellent technical indicators: The channel spacing of this module is 100GHz, the channel uniformity is as high as ±0.05dB, the channel insertion loss is as low as below 5dB, and the channel isolation is above 25dB, which can provide users with more efficient data transmission.
4. Easy to use: The module supports RS232 management interface and single 12V power supply, easy to operate and easy to integrate.
Product Image

Product Applications
1. Communication field: This module is widely used in the communication field and can provide a reliable solution for high-speed data transmission. In scenarios such as data centers, network backbones, and optical transport networks, this module can meet the needs of high-speed data transmission and improve communication efficiency and stability.
2. Radio and television field: This module is also applicable to the field of radio and television, and can support the transmission of high-definition video, audio and other content. In scenarios such as radio and television transmission, radio satellite, and cable TV, the module can provide high-speed, stable, and reliable data transmission services.
3. Computer room field: This module is also applicable to the computer room field, which can provide a more stable guarantee for data transmission inside the computer room. In scenarios such as data storage, server interconnection, and cloud computing, this module can provide high-speed, low-latency data transmission services and improve data processing efficiency in the computer room.
4. Other fields: In addition to the above three fields, this module is also applicable to other fields, such as scientific research, medical equipment and other fields. In these fields, the module can provide high-speed, high-precision data transmission services to meet the needs of different users for data transmission.
Product Parameters
| Number of channels | 48 channels | Channel Spacing | 100 GHz |
| Center Wavelength | 1550 nm | Bandwidth range | C-band (1525 nm - 1565 nm) |
| Channel Uniformity | ±0.05 dB | Channel insertion loss | ≤4.5 dB |
| Channel Isolation | ≥25 dB | Adjacent channel isolation | ≥30 dB |
| Non-adjacent channel isolation | ≥40 dB |
Instructions For Use
1. Connecting equipment: connect the 100G 48-channel Flat Top Gaussian AAWG module with other equipment. The module supports RS232 management interface and single 12V power supply, you need to use the corresponding interface and power supply for connection.
2. Setting parameters: Using the RS232 management interface, you can set the parameters of the module. These parameters include number of channels, channel spacing, channel uniformity, channel insertion loss, channel isolation, etc. Set appropriate parameters according to your needs.
3. Start the module: After setting the parameters, you can start the module. At this point, the module starts to work, providing high-speed, stable and reliable data transmission services.
4. Monitoring module: During use, you can monitor the working status of the module through the RS232 management interface. You can check the number of channels, channel uniformity, channel insertion loss, channel isolation and other parameters of the module to ensure the normal operation of the module.
Terms Of Use
1. Please read the instructions carefully before use: Before using the 100G 48-channel Flat Top Gaussian AAWG module, you need to read the instructions carefully. Understand the parameters, functions and usage methods of the modules to ensure the correct use of the modules.
2. Safe use of power supply: The module is powered by a single 12V power supply, please ensure correct wiring and follow safe operating procedures to avoid power failures and safety accidents.
3. Avoid excessive stretching and bending of optical fibers: During use, it is necessary to avoid excessive stretching and bending of optical fibers, so as not to affect the working effect of the module.
4. Avoid excessive vibration and collision: the module is a precision instrument, avoid excessive vibration and collision, so as not to affect the performance and life of the module.
5. Maintain a good ventilation environment: During use, it is necessary to maintain a good ventilation environment to avoid overheating and excessive humidity, so as not to affect the working effect and life of the module.
6. Regular maintenance and maintenance: Regular maintenance and maintenance of the module, including cleaning, inspection, replacement of parts, etc., to ensure the normal operation and life of the module.
Customer Comments