Optical Line Protection Card
Gracyfiber OLP Optical Line Protection is used in the protection of network transmission line, the product can realize optical power monitoring and automatic switching. In optical communication network, OLP real-time monitoring optical power of working optical fiber and standby optical fiber. When the optical power value of working optical fiber is below the set switching threshold, the system raise the alarm prompt and switches to standby fiber automatically, which achieve line protection of optical transmission system
- Product Introduction
The optical communication line transmission protection card is a high-reliability, low-loss optical communication protection device, which can be widely used in optical communication networks, data centers, telecom operators, military communications and other fields, providing users with high-quality, high-reliability Optical communication protection services.
The product adopts advanced optical technology and electronic control technology, and has the advantages of fast switching speed, low loss, and high reliability. In the optical fiber communication network, once the main line fails, the protection card can quickly switch to the backup line, so as to ensure the continuity and reliability of data transmission and protect the security of important data of users.
Our optical communication line transmission protection card has passed a number of international certifications, including CE certification, FCC certification, etc., and the product quality has been widely recognized. We will, as always, be committed to providing users with high-quality, highly reliable optical communication protection equipment, and provide reliable protection for users' business development.
Product Features
1. Fast switching: The optical communication line transmission protection card adopts fast switching technology, and the switching time usually does not exceed 50ms, so as to ensure the continuity and reliability of data transmission.
2. Low loss: The optical communication line transmission protection card uses low-loss optical devices to ensure the quality and stability of data transmission.
3. High reliability: The product adopts advanced electronic control technology and optical technology, has high reliability and stability, and can effectively protect the data transmission of the optical fiber communication network.
4. Easy to install: The installation and debugging of the optical communication line transmission protection card is very convenient, and users can configure it flexibly according to actual needs.
5. Strong scalability: This product can be used in conjunction with other optical communication equipment, such as optical amplifiers, optical splitters, etc., to build a variety of different optical fiber communication network topologies.
Product Image



Product Applications
1. Optical fiber communication network: The optical communication line transmission protection card can be applied to various network topologies such as optical fiber ring network and optical fiber point-to-point to ensure the stability and reliability of data transmission.
2. Data center: With the continuous expansion of the data center scale, the reliability and stability of data transmission are getting more and more attention. The optical communication line transmission protection card can be applied to the optical fiber communication network of the data center to provide reliable protection for data transmission.
3. Telecom operators: Optical communication line transmission protection cards can be applied to optical fiber communication networks of telecom operators to ensure the quality and reliability of communication services and provide users with high-quality communication services.
4. Military communication: The optical communication line transmission protection card can be used in the field of military communication to provide reliable protection for military communication equipment and ensure the security and stability of communication information.
Product Parameters
| Fiber Interface Type | SC/UPC, LC/UPC, FC/UPC, ST/UPC | Working wavelength | 1310nm/1550nm |
| Protection switching time | Within 50ms | Transition Loss | Within 1dB |
| Return Loss | Above 50dB | Working temperature | -10℃~60℃ |
| Working Voltage | DC 5V |
Instructions For Use
1. Install the optical communication line transmission protection card in a suitable position, generally between the main line and the backup line, and connect with other optical communication equipment at the same time.
2. Configure according to actual needs, including setting of main line and backup line, setting of protection switching time, etc.
3. After the protection card is installed and configured, it is necessary to perform tests, including tests of the main line, backup line, and protection switching time.
4. After passing the test, put the protection card into operation. The protection card will automatically monitor the status of the main line. Once the main line fails, the protection card will automatically switch to the backup line to ensure the continuity and reliability of data transmission.
Terms Of Use
1. The optical communication line transmission protection card should be installed between the main line and the backup line, and the distance from the two lines should not be too far to ensure switching speed and quality.
2. When connecting optical fibers, the correct optical fiber connection method should be used to ensure the quality and stability of the optical fibers and avoid failures caused by poor connections.
3. The protection card needs a stable power supply, and standard power supply equipment should be used to avoid failures caused by insufficient power supply or power fluctuations.
4. When configuring the protection card, it should be configured according to the actual needs, including the setting of the main line and backup line, the setting of the protection switching time, etc., to avoid faults caused by wrong configuration.
5. After the protection card is installed and configured, it is necessary to test, including the main line, backup line test, and protection switching time test, etc., to ensure the normal operation of the protection card.
6. Regularly maintain the optical communication line transmission protection card, including cleaning, inspection, replacement of parts, etc., to ensure the normal operation of the protection card.
Customer Comments
Alexandra Fischer, a network engineer in Munich, commented:
Juan Rodriguez, System Administrator in Mexico City commented:
Elena Petrov, a communications engineer in Moscow, commented:
Sofia Andersson, System Architect in Stockholm, commented:
Dublin network architect Liam O'Connor commented:
Related Blogs
Product Video